Rapid assessment of the continuous glucose monitoring (CGM real-time) and flash glucose monitoring (FGM) by the EUnetHTA

18

Sep 2018

The author of this report is the Croatian Agency for Quality and Accreditation in Health Care and Social Welfare (AAZ), with the co-authors being the Norwegian Institute of Public Health (NIPHNO) and the Main Association of Austrian Social Security Institutions (HVB).

The authors addressed the following research question: whether the use of real-time continuous glucose monitoring (rtCGM) and flash glucose monitoring (FGM) medical devices as personal, standalone systems, being adjunctive (cannot be used to make treatment decision without confirmatory finger-stick testing) or non-adjunctive (can be used to make treatment decision without confirmatory finger-stick testing) in patients with diabetes mellitus type 1 and type 2 (T1DM and T2DM) in adults and children, gestational DM patients using insulin, either through insulin pump therapy (CSII) or multiple daily insulin injections (MDII), is more effective and/or safer than using self-monitoring blood glucose (SMBG) medical devices.

The selection of assessment elements was based on the EUnetHTA Core Model® Application for Rapid Relative Effectiveness (REA) Assessments. A new systematic review (SR) of RCTs with a meta-analysis on one clinical outcome (HbA1C change) was performed. Study, outcomes validity and level of evidence were assessed following the EUnetHTA guidelines. The Cochrane Risk of Bias Tool was used both on study and outcome levels, and GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) tool was used to assess the certainty of the body of evidence were used.

Twelve (12) RCTs reported on the use of rtCGM (as standalone devices or with insulin pumps) and FGM devices compared with SMBG. Only one head-to-head trial was identified comparing rtCGM and FGM. Three nRCTs were included in the safety domain in addition to those RCTs included in the clinical effectiveness domain.

Conclusion

The use of CGM devices assessed was associated with a reduction in HbA1c in the majority of the studies that included MDII treated patients and in the two studies with MDII and CSII treated patients; both CGM and FGM devices assessed were associated with reduction in hypo- and hyperglycaemia outcomes and improved treatment satisfaction in patients with T1 or T2DM, compared with SMBG. No RCTs were found investigating devices assessed with CE mark authorization in pregnancy. Further high-quality head-to-head studies are needed on long-term relative effectiveness and safety comparing CGM and FGM devices, especially in children and pregnancy. Adults, children, and parents with T1 DM reported very positive experiences with CGM and FGM devices; different benefits were shown as well as the most critical barriers – high cost and unavailability of these medical devices in some countries.

See the full report in English here.

Subscribe to our newsletter delivered every second week not to miss important reimbursement information.

The latest related news

24

Mar 2022

The HTA body of the Tuscany Regional Healthcare issues two types of documents: HTA forms and motivational forms. With a regional decree 2472 of February 10, 2022, Tuscany Regional Healthcare has published assessments of five medical devices of various therapeutic areas, such as cardiovascular and peripheral vascular areas.

Read more

16

Mar 2022

In February 2022, Swedish Medical Technologies Product (MTP) Council issued an updated recommendation on FreeStyle Libre for continuous glucose monitoring in type 2 diabetes (T2D). The initial recommendations were published by NT Council in 2018 and updated by MTP Council in 2020 to include FreeStyle Libre 2. In the 2022 update, MTP Council decreased the Hba1c limit from 70 to 60 mmol/mol and added a statement on lifestyle changes and treatment optimization with non-insulin antidiabetic drugs.

Read more

15

Mar 2022

The Belgian Health Care Knowledge Center (KCE) initiated a study aimed at defining a clear and transparent procedure for the evaluation of digital health technologies in Belgium.

Read more

11

Mar 2022

On February 07, 2022, the Dental and Pharmaceutical Benefits Agency has announced the withdrawal of the assessments of the PhysioMem PM 100 and CardioMem CM 100 XT and the finalization of the assessments of the Zenicor ECG, Coala Heart Monitor Pro, and KardiaMobile. For the conducted assessments, it was outlined that the portable devices provide more limited information than standard ECG measurements; therefore, it was mainly estimated for atrial fibrillation.

Read more

10

Mar 2022

In February 2022, the Finnish Coordinating Center for Health Technology Assessment announced the release of the seven accomplished rapid hospital assessments performed by the Helsinki, Tampere, and Oulu University Hospital. The accomplished rapid HTAs concern the diagnostic imaging, e-Health, endocrine, endoscopy, men’s health, neuromodulation technology groups.

Read more